Biomimetic Architectural Cover Accelerates Osseointegration of Titanium Implants

Journal of Bone Metabolism 2026;33(1):30-39.
Published online: February 28, 2026

1Department of Pharmacology and Dental Therapeutics, School of Dentistry, Chonnam National University, Gwangju, Korea

2Hard-Tissue Biointerface Research Center, School of Dentistry, Chonnam National University, Gwangju, Korea

3Department of Mechanical Engineering, Wonkwang University, Iksan, Korea

4Division of Mechanical Engineering, Wonkwang University, Iksan, Korea

5MECHABIO Group, Wonkwang University, Iksan, Korea

6Advanced Bio-Convergence Research Center, Wonkwang University, Iksan, Korea

Corresponding author: Je-Hwang Ryu, Department of Pharmacology and Dental Therapeutics, School of Dentistry, Chonnam National University, 33 Yongbong-ro, Buk-gu, Gwangju 61186, Korea, Tel: +82-62-530-4863, Fax: +82-62-530-4807, E-mail: jesryu@jnu.ac.kr
• Received: December 19, 2025   • Revised: January 7, 2026   • Accepted: January 22, 2026

Copyright © 2026 The Korean Society for Bone and Mineral Research

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

  • 2,024 Views
  • 43 Download
prev next
  • Background
    Although various surface modifications enhance titanium (Ti) implant osseointegration, achieving rapid bone formation comparable to native healing remains challenging. Current strategies primarily focus on micro-scale topography, often overlooking the critical role of macroscopic three-dimensional (3D) architecture in osteoconduction.
  • Methods
    We hypothesized that mimicking native bone’s porous architecture is key to accelerating osseointegration. First, we verified the impact of structural continuity by comparing standard Ti implants with decellularized bone grafts in a mouse calvaria defect model. Subsequently, we developed a biomimetic polycaprolactone (PCL)-based 3D architectural cover (Cover-type) and evaluated its osseointegration efficacy in a rat femur model against conventional Ti implants.
  • Results
    The mouse study confirmed that decellularized bone integrated significantly faster than Ti, highlighting the necessity of 3D continuity. In the rat model, micro-computed tomography analysis indicated a clear trend of increased bone formation in the Cover-type group, though statistical significance was limited by sample size. However, histological analysis confirmed a statistically significant enhancement in bone-to-implant contact compared to controls (P<0.05). The PCL structure served as a scaffold for cell migration, effectively bridging the implantbone gap.
  • Conclusions
    These findings suggest that providing a bone-like 3D environment via a PCL cover may enhance histological osseointegration, rather than relying solely on surface chemistry.
Dental implants are widely used to replace missing teeth and generally demonstrate high long-term survival rates in clinical studies.[1] With the increasing demand for shorter overall treatment times and earlier restoration of function, immediate or early loading protocols have become a standard objective in implant dentistry.[2] However, achieving and maintaining adequate primary stability remains a significant challenge in regions of reduced or poor bone quality, such as low-density trabecular bone.[3] Consequently, the rate and quality of early osseo integration are critical determinants of implant stability and long-term clinical success, particularly in these compromised bone conditions.[4]
To accelerate peri-implant healing, surface modification strategies—including sandblasting with large-grit and acid-etching, anodization, and bioactive coatings—have been extensively developed. These methods tailor surface topography and chemistry to modulate early host responses, such as protein adsorption, platelet activation, and initial cell adhesion.[5,6] However, these approaches primarily act at the implant interface and do not directly control the macro-scale healing space within and around the implant threads. Early after placement, the peri-implant gap is filled with a blood clot that functions as a provisional wound matrix; the stabilization of this clot and its timely replacement by granulation tissue are critical for subsequent bone formation.[7,8] Despite surface advancements, bone fill within the thread valleys is often the ratelimiting step in healing, especially when the early wound matrix is insufficiently stabilized. This delay in “distance osteogenesis” can compromise biological fixation in the critical early weeks.[9,10]
To move beyond surface-centric limitations, we sought to identify additional structural determinants of rapid bone integration. Autogenous bone remains the clinical benchmark because it uniquely combines osteogenic, osteoinductive, and osteoconductive properties.[11] Notably, accumulating evidence indicates that scaffold architecture—particularly interconnected porosity and channel networks—plays a pivotal role in enabling vascular ingrowth and osteogenic cell migration deep into the defect. [12] Guided by this biological insight, we performed a preliminary proof-of-concept study in a mouse calvarial defect model, comparing a size-matched solid titanium (Ti) implant with a bone-derived decellularized bone matrix (dBM) construct.[13] Consistent with the importance of native-like architecture, the bone-matrix construct exhibited superior structural continuity and integration with the surrounding host bone compared to the Ti disk.
Based on these findings, we propose shifting the design focus from microscale surface roughening to macroscale architectural engineering of the peri-implant healing space. Since autologous bone is not always available, a synthetic alternative that recapitulates the key structural features of native bone is required. Polycaprolactone (PCL) is a biodegradable polymer with established safety in U.S. Food and Drug Administration-regulated devices and is highly amenable to additive manufacturing.[14] Three-dimensional (3D) printing enables the precise fabrication of engineered porous architectures with controlled geometry.[ 15] In this study, we developed a PCL-based architectural cover designed to overlay the Ti implant. By introducing an interconnected porous network, the cover is intended to convert the peri-implant gap from a passive void into a structurally guided space that actively supports osteoconductive tissue ingrowth.
The primary objective of this study was to evaluate whether this biomimetic architectural cover could translate the rapid integration observed in dBM to synthetic Ti implants. We fabricated the Cover-type implant and assessed its osseointegration efficacy in a rat femur model, a clinically relevant load-bearing environment. We employed micro-computed tomography (micro-CT) and histomorphometric analysis to quantify new bone volume and bone-to-implant contact (BIC). Our findings demonstrate that recapitulating the 3D architecture of native bone via a PCL cover significantly accelerates osseointegration compared to conventional Ti surfaces, suggesting a novel strategy for enhancing implant performance in challenging clinical conditions.
1. Fabrication of 3D-printed PCL-based cylindrical scaffold
To fabricate the scaffold, medical-grade PCL (C209; Evonik Industry, Essen, Germany) was used as the raw material. The PCL was loaded into a 50 mL stainless steel barrel (SS50; U-Jin Tech., Siheung, Korea) and melted at 85°C for over 30 min. The molten PCL was then printed using a custom-made 3D printing system through a precision extrusion nozzle (PRN0.15; U-Jin Tech.). The scaffold was designed with a cylindrical geometry to ensheathe the Ti fixture. To facilitate the infiltration of osteogenic cells and blood, and to maximize the surface area for cell attachment, a dimpled surface texture and a uniform circumferential porous structure were introduced using a dragging technique.[16] Prior to surgical implantation, all fabricated scaffolds were sterilized using ethylene oxide gas.
2. Mouse calvarial defect model
Male wild-type C57BL/6 mice (8 weeks old) were used to assess the impact of structural architecture on bone healing. A 5-mm critical-size circular defect was created in the parietal bone using a trephine bur (Fine Science Tools, Foster City, CA, USA), carefully preserving the underlying dura mater. The defects were filled with either a dimension-matched solid Ti disk or a dBM. Prior to implantation, dBM disks were sterilized by immersion in 70% ethanol, extensively rinsed in sterile phosphate-buffered saline (PBS), and confirmed to be free of visible cellular structures by histological examination. Mice were euthanized at 2, 4, 6, or 8 weeks post-surgery, and the calvariae were harvested for micro-CT-based assessment of defect closure and host-implant integration.
3. Rat distal femur implantation model
Seven-week-old male Sprague-Dawley rats (200–300 g) were used for the load-bearing implant model. All animal procedures were approved by the Institutional Animal Care and Use Committee (IACUC) of Chonnam National University (Approval No. IACUC-YB-2025-118). Animals were randomly allocated to either the implant-only control group or the cover-type scaffold-augmented implant group (N=3). Outcome assessments were performed by an investigator blinded to group allocation. Under general anesthesia and perioperative analgesia, the distal femur was exposed via a lateral approach under aseptic conditions. A cylindrical osteotomy was prepared perpendicular to the femoral long axis using a 3-mm drill bit under continuous sterile saline irrigation to minimize thermal injury. The implants were surgically placed into the osteotomy site. (Note: Given the osteotomy diameter of 3 mm and the scaffold outer diameter of approximately 2.76 mm, this setup functioned as a gap-healing model, relying on biological integration rather than initial press-fit stability.) Prior to implantation, Ti fixtures were autoclaved, and PCL scaffolds were disinfected by immersion in 70% ethanol followed by three rinses with sterile PBS. At 8 weeks post-implantation, rats were euthanized, and femurs were harvested and fixed in 10% neutral buffered formalin for subsequent analyses.
4. Micro-CT analysis
Harvested femoral specimens were scanned using a Quantum FX micro-CT imaging system (Quantum FX micor-CT; Revvity, Hopkinton, MA, USA). Scans were acquired using a manufacturer-defined protocol (FOV, 10 mm; 90 kV, 160 μA; scan time, 180 sec). Reconstructed volumes were exported as DICOM datasets and processed for 3D visualization and quantitative analysis. To assess osteoconductive bone ingrowth, the region of interest (ROI) was segmented into two distinct zones: an outer zone corresponding to the thread crest (periphery) and an inner zone corresponding to the thread valleys. Mineralized tissue within each zone was segmented using a global threshold. To minimize Ti-related beam-hardening/blooming effects during threshold-based segmentation, the high-density implant/scaffold region was segmented first and used as an exclusion mask (masking/editable area) so that bone thresholding was restricted to voxels outside the metal/scaffold mask, thereby reducing grey-value–driven segmentation bias near the implant boundary. Bone formation was quantified as the bone volume fraction (BV/TV, %), where the total volume (TV) was defined as the available ROI volume excluding the scaffold volume (TV = ROI volume − scaffold volume).
5. Histological analysis (non-decalcified resin sections)
Following micro-CT scanning, specimens were re-fixed in fresh 10% neutral buffered formalin for 2 to 3 days, rinsed in running tap water for 6 hr, and dehydrated through a graded ethanol series (70%, 80%, 90%, and 100%). Samples were infiltrated with a light-curing resin (Technovit 7200 VLC; Kulzer Technik, Wehrheim, Germany) using stepwise ethanol/resin mixtures, followed by infiltration in 100% resin for one week under vacuum. Embedded blocks were polymerized using a light-polymerization unit (EXART 520; EXAKT Advanced Technologies, Norderstedt, Germany). The blocks were sectioned to an initial thickness of approximately 400 μm using a diamond band saw (EXAKT 300; EXAKT Advanced Technologies) and subsequently ground and polished to a final thickness of 15 to 30 μm using a precision grinding system (EXAKT 400 CS; EXAKT Advanced Technologies). Sections were stained with hematoxylin and eosin (H&E) and examined under a light microscope (BX50; Olympus, Tokyo, Japan). Histomorphometric BIC was quantified on digital images using Aperio ImageScope (Leica Biosystems, Wetzlar, Germany) by measuring the percentage of the implant surface in direct contact with mineralized bone. For histomorphometric analysis, one non-decalcified section was obtained and analyzed per animal due to technical limitations inherent to the resin embedding and sectioning process. BIC was quantified from this section, and statistical analyses were performed at the animal level (N=3 per group).
6. Statistical analysis
All quantitative data are presented as mean±standard deviation (SD). Statistical comparisons between the Control and Cover-type groups were performed using the Mann-Whitney U test, considering the sample size (N=3). A P value of less than 0.05 (P<0.05) was considered statistically significant. All statistical analyses were conducted using GraphPad Prism 10.0 (GraphPad Software Inc., La Jolla, CA, USA).
1. Calvarial defect bridging by decellularized bone disks
To examine whether 3D architecture influences osseointegration in a critical-size defect, we compared the healing responses of a size-matched dBM disk and a solid Ti disk in a 5-mm mouse calvarial defect model (Fig. 1A). Longitudinal micro-CT reconstructions revealed distinct integration patterns between the two groups (Fig. 1B). In the dBM group, defect bridging progressed steadily over time, and the host-implant interface exhibited structural continuity while preserving the porous microarchitecture. By 8 weeks, the boundary between the graft and the surrounding host bone became minimally discernible, indicating seamless integration. In contrast, the Ti disk group exhibited bone formation predominantly at the defect margins with a persistent radiolucent interfacial zone throughout the observation period, indicating limited structural integration. These findings support the concept that an interconnected porous architecture facilitates osteoconductive bone ingrowth and accelerates structural incorporation within the defect.
2. Structural characteristics of the 3D-printed PCL scaffold
The fabricated PCL-based scaffold featured a cylindrical geometry designed to ensheathe the Ti implant. The overall architecture was based on a radial grid structure, where two distinct patterns (Type 1 and Type 2) were alternately stacked. Additionally, a uniform porous structure was introduced in the circumferential region using a dragging technique to enhance surface area (Fig. 2A).[16] Optical imaging confirmed that the scaffold dimensions were tailored to the implant size, with a height of approximately 5.4 mm, an inner diameter of 1.75 mm, and an outer diameter of 2.76 mm. The inter-strand distance and strand thickness were measured to be approximately 200 μm and 150 μm, respectively. Furthermore, the pore size in the circumferential area was uniformly distributed within the range of 200 to 230 μm on both the inner and outer surfaces (Fig. 2B), providing an optimal microenvironment for cellular infiltration.
3. Micro-CT assessment of peri-implant bone ingrowth
We evaluated osseointegration in the rat distal femur model by comparing the implant-only control group with the cover-type scaffold-augmented group (Fig. 3). At 8 weeks post-implantation, peri-implant bone formation was assessed using predefined ROIs that differentiated the thread crest (outer ROI) from the thread valley (inner ROI) (Fig. 4A). Representative 3D renderings indicated a visibly higher density of mineralized tissue extending into the thread valleys in the cover-type group compared to the control (Fig. 4B). Quantitative analysis revealed that the BV/TV (%) was numerically higher in the cover-type group across both ROIs. Although these volumetric differences did not reach statistical significance (Mann-Whitney U test; P>0.05) likely due to the limited sample size (N=3) and metallic artifacts, a clear positive trend of increased bone formation was observed, particularly within the inner ROI (thread valleys) where the scaffold bridged the gap between the implant and host bone (Fig. 4C).
4. Histological confirmation of osseointegration
Histological evaluation with H&E staining provided definitive evidence of osseointegration, overcoming the resolution limits of micro-CT. In the control group, sections frequently displayed a layer of fibrous connective tissue intervening at the interface between the implant surface and the host bone, indicating incomplete osseointegration. In contrast, the cover-type group demonstrated direct bone apposition to the implant surface, with new bone effectively filling the pores of the PCL scaffold and integrating continuously with the adjacent native bone (Fig. 5A). The Cover-type group showed a significantly higher BIC compared with the control group (P=0.0368). Crucially, histomorphometric analysis of the BIC confirmed that the cover-type group achieved a significantly higher BIC ratio than the control group (P<0.05; Fig. 5B). This statistically significant finding validates that the PCL architectural cover effectively guided osteogenesis to the implant surface, bridging the peri-implant gap.
The primary finding of this study is that providing a macroscopic porous architecture around the implant significantly accelerates osseointegration. Our initial proof-of-concept in the mouse calvaria model demonstrated that structural continuity—exemplified by the dBM—is critical for rapid healing. Whereas conventional Ti surface modifications mainly enhance contact osteogenesis at the implant interface, an interconnected porous architecture can promote osteoconductive ingrowth. It achieves this by facilitating vascularization and osteogenic cell migration, thereby supporting bone formation within the often-delayed peri-implant gaps and thread valleys.[17] Translating this biological insight into a synthetic model, we utilized a PCL cover. While synthetic PCL cannot fully recapitulate the hierarchical nanocomposite architecture of native bone,[18,19] our findings indicate that its engineered macroporosity provides a permissive scaffolding that converts the peri-implant void into a biologically active zone.
The importance of pore size and interconnectivity in bone scaffolds has been widely documented.[20] Although optimal pore sizes are debated, the range of 100 to 500 μm is generally considered effective for osteogenesis.[21,22] Leveraging our dragging 3D-printing technique, we successfully fabricated strut-like architectures with interconnected pores within this optimal range (200–230 μm). In our rat femur model, this architecture played a crucial role in bridging the gap between the osteotomy site (3 mm) and the implant assembly (~2.76 mm). Unlike press-fit scenarios where primary stability relies on mechanical locking, our model relied on the scaffold’s ability to guide rapid tissue ingrowth. This confirms that the PCL cover effectively functions as a “healing chamber,” stabilizing the blood clot and guiding the organization of granulation tissue into woven bone even in the absence of initial tight contact. [23,24]
A notable observation in this study was the discrepancy between the volumetric micro-CT trends and the statistically significant histological outcomes. While micro-CT analysis indicated a positive trend in BV/TV for the Covertype group, it did not reach statistical significance. This can be attributed to the limited sample size (N=3) and the inherent challenges of micro-CT imaging around Ti implants, where beam-hardening artifacts may obscure the precise quantification of mineralized tissue at the immediate interface. Importantly, micro-CT and histological analyses capture non-equivalent dimensions of osseointegration. Whereas micro-CT reflects volumetric mineralized tissue formation, histological BIC assesses direct bone apposition at the implant interface. Because the architectural cover guides bone growth toward the implant surface rather than uniformly increasing bone volume, BIC may increase without a corresponding statistically significant change in BV/TV. Histological evaluation was performed on a single representative section per animal, which represents a limitation and supports the exploratory nature of these findings. Despite this limitation, the observed difference in BIC was biologically meaningful. However, histological analysis, which offers higher resolution and is free from metallic artifacts, definitively resolved this ambiguity. The histomorphometric results demonstrated a statistically significant increase in BIC (P<0.05). This suggests that while the total mineralized volume within the ROI may vary, the quality of integration and the direct apposition of bone to the implant surface—the critical metrics for osseointegration—were significantly enhanced by the PCL architectural cover.
Despite these promising findings, certain limitations warrant discussion. First, the addition of the PCL cover introduced geometric variables that differentiated the experimental group from the control (Ti-only) group, particularly regarding the gap distance. To mitigate this, we employed segmented ROI analysis (inner vs. outer zones) to normalize the evaluation of bone ingrowth. The architectural cover alters the local healing geometry and may provide partial mechanical stabilization of the peri-implant gap. Therefore, the observed enhancement of peri-implant bone healing likely reflects a combined contribution of mechanical stabilization and guided osteogenesis, rather than osteogenesis alone. Future studies aim to standardize the defect-to-implant ratios to enable more precise geometric comparisons.[25] Second, biomechanical testing, such as removal torque analysis, was not performed in this study due to the anatomical constraints of the rat femur model and the specific configuration of the scaffold. Although we relied on biological parameters, the significantly higher BIC observed in the Cover-type group serves as a strong biological surrogate for improved mechanical stability.[ 26] The significantly higher BIC observed in the Cover-type group indicates enhanced interfacial osteogenesis; however, it should not be interpreted as direct evidence of mechanical fixation, as biomechanical competence was not directly evaluated in this study. Accordingly, functional validation using biomechanical tests such as removal torque or push-out analysis will be required in future studies to confirm the mechanical implications of the architectural cover. Future research utilizing larger animal models (e.g., beagle dogs) is essential to quantitatively verify the biomechanical retention force and the long-term load-bearing capacity of the PCL-Ti interface.
While the rat femur model provides a load-bearing healing context, its anatomical and biological characteristics differ substantially from those of alveolar bone, including differences in bone remodeling dynamics and local mechanical environments. Accordingly, the clinical implications of these findings for dental implant applications should be interpreted cautiously, and further validation in jawbone-specific and large-animal models will be required. Clinically, the concept of an architectural cover holds significant potential, particularly for patients with low-density bone where achieving and maintaining early stability is challenging. Given the slow degradation profile of PCL, potential long-term interactions between residual scaffold material and peri-implant tissues should be considered in future studies, although the same property may allow sustained structural support and progressive load sharing as newly formed bone matures. Furthermore, the PCL framework offers a versatile platform for incorporating osteoinductive cues, such as bone morphogenetic protein-2,[27] which could further synergize structural osteoconduction with biological osteoinduction.
In conclusion, this study demonstrates that a PCL-based architectural cover enhances histological osseointegration by guiding interfacial bone formation in a gap-healing context. Within the limitations of this exploratory study, architectural guidance shows potential as a complementary strategy for improving peri-implant bone healing. Further studies incorporating biomechanical testing and jawbone-specific large-animal models will be required to establish the functional and translational relevance of this approach.

Acknowledgments

During manuscript preparation, ChatGPT (OpenAI) was used for proofreading and sentence-level language edits.

Funding

This work was supported by the National Research Foundation of Korea (NRF) grants funded by the Korean government (2021R1A2C3005727 and RS-2024-00454010), and by the Korean Fund for Regenerative Medicine (KFRM) grant, funded by the Korean government (the Ministry of Science and ICT, the Ministry of Health & Welfare). (22A01 04L1).

Ethics approval and consent to participate

All animal procedures were approved by the IACUC of Chonnam National University and were conducted in accordance with applicable institutional guidelines.

Conflict of interest

No potential conflict of interest relevant to this article was reported.

Fig. 1
Comparison of distinct osseointegration patterns between decellularized bone and titanium disks in a mouse calvarial critical-size defect model. (A) Schematic illustration of the surgical procedure. A 5-mm-diameter critical-sized defect was created in the mouse calvaria, followed by the implantation of a size-matched decellularized bone matrix disk or a solid titanium disk. (B) Micro-computed tomography reconstructions showing the healing progression. The decellularized bone disk group (upper) demonstrates progressive defect bridging and structural continuity at the host-implant interface, preserving the native porous microarchitecture. In contrast, the titanium group (lower) exhibits bone formation limited to the defect margins with a persistent radiolucent interfacial zone, indicating limited structural integration.
jbm-26-1003f1.jpg
Fig. 2
Design and fabrication of the three-dimensional (3D) printed polycaprolactone (PCL)-based architectural cover. (A) Structural schematic of the cylindrical scaffold designed to ensheathe the implant fixture. (B) Representative optical images of the fabricated scaffold. The dragging technique was employed to create a uniform, interconnected porous network (pore size=200–230 μm) to facilitate cellular infiltration and vascularization.
jbm-26-1003f2.jpg
Fig. 3
Experimental design and surgical workflow for the rat distal femur implantation model. (A) Study timeline and schematic of the surgical procedure. Dental implants were placed in the distal femur of Sprague-Dawley (SD) rats. The osteotomy diameter (3 mm) was larger than the implant assembly (~2.76 mm) to create a gap-healing model. Rats were assigned to either an implant-only control group or a cover-type scaffold-augmented implant group. (B) At 8 weeks post-implantation, rats were euthanized, and femurs were harvested for three-dimensional micro-computed tomography (CT) and histological analyses to evaluate osseointegration. H&E, hematoxylin and eosin.
jbm-26-1003f3.jpg
Fig. 4
Three-dimensional (3D) micro-computed tomography (CT) assessment of peri-implant bone formation. (A) Definition of the regions of interest (ROIs) for quantitative analysis. The outer ROI encompasses the peri-implant region at the thread crest (periphery), whereas the inner ROI corresponds to the thread valley region (valley depth). (B) Representative 3D micro-CT volume renderings of the implant-only control and cover-type scaffold-augmented groups. Micro-CT images were reconstructed using identical visualization parameters across all groups (scale bar=500 μm). A visible trend of increased mineralized tissue distribution within the thread valleys is observed in the cover-type group. (C) Quantification of bone volume (BV) fraction (BV/total volume [TV], %) within the inner and outer ROIs. The data is presented as mean±standard deviation (N=3). While statistical significance was not reached due to sample size limitations (P>0.05, Mann-Whitney U test), the cover-type group exhibits a higher mean BV, particularly in the inner ROI. 2D, two-dimensional.
jbm-26-1003f4.jpg
Fig. 5
Histological confirmation of enhanced osseointegration and bone-to-implant contact (BIC). (A) Representative hematoxylin and eosin (H&E)-stained sections from the implant-only control and cover-type scaffold-augmented groups at 8 weeks post-implantation. The cover-type group shows new bone trabeculae traversing the scaffold pores to achieve direct contact with the implant surface (bridging the gap), whereas the control group frequently shows interfacial fibrous tissue encapsulation (scale bar=500 μm). (B) Histomorphometric quantification of the BIC (%). The data is presented as mean±standard deviation. The cover-type group demonstrated a statistically significant increase in BIC compared to the control group. a)P<0.05, Mann-Whitney U test.
jbm-26-1003f5.jpg
jbm-26-1003f6.jpg

Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:

Include:

Biomimetic Architectural Cover Accelerates Osseointegration of Titanium Implants
J Bone Metab. 2026;33(1):30-39.   Published online February 28, 2026
Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:
Include:
Biomimetic Architectural Cover Accelerates Osseointegration of Titanium Implants
J Bone Metab. 2026;33(1):30-39.   Published online February 28, 2026
Close

Figure

  • 0
  • 1
  • 2
  • 3
  • 4
  • 5
Biomimetic Architectural Cover Accelerates Osseointegration of Titanium Implants
Image Image Image Image Image Image
Fig. 1 Comparison of distinct osseointegration patterns between decellularized bone and titanium disks in a mouse calvarial critical-size defect model. (A) Schematic illustration of the surgical procedure. A 5-mm-diameter critical-sized defect was created in the mouse calvaria, followed by the implantation of a size-matched decellularized bone matrix disk or a solid titanium disk. (B) Micro-computed tomography reconstructions showing the healing progression. The decellularized bone disk group (upper) demonstrates progressive defect bridging and structural continuity at the host-implant interface, preserving the native porous microarchitecture. In contrast, the titanium group (lower) exhibits bone formation limited to the defect margins with a persistent radiolucent interfacial zone, indicating limited structural integration.
Fig. 2 Design and fabrication of the three-dimensional (3D) printed polycaprolactone (PCL)-based architectural cover. (A) Structural schematic of the cylindrical scaffold designed to ensheathe the implant fixture. (B) Representative optical images of the fabricated scaffold. The dragging technique was employed to create a uniform, interconnected porous network (pore size=200–230 μm) to facilitate cellular infiltration and vascularization.
Fig. 3 Experimental design and surgical workflow for the rat distal femur implantation model. (A) Study timeline and schematic of the surgical procedure. Dental implants were placed in the distal femur of Sprague-Dawley (SD) rats. The osteotomy diameter (3 mm) was larger than the implant assembly (~2.76 mm) to create a gap-healing model. Rats were assigned to either an implant-only control group or a cover-type scaffold-augmented implant group. (B) At 8 weeks post-implantation, rats were euthanized, and femurs were harvested for three-dimensional micro-computed tomography (CT) and histological analyses to evaluate osseointegration. H&E, hematoxylin and eosin.
Fig. 4 Three-dimensional (3D) micro-computed tomography (CT) assessment of peri-implant bone formation. (A) Definition of the regions of interest (ROIs) for quantitative analysis. The outer ROI encompasses the peri-implant region at the thread crest (periphery), whereas the inner ROI corresponds to the thread valley region (valley depth). (B) Representative 3D micro-CT volume renderings of the implant-only control and cover-type scaffold-augmented groups. Micro-CT images were reconstructed using identical visualization parameters across all groups (scale bar=500 μm). A visible trend of increased mineralized tissue distribution within the thread valleys is observed in the cover-type group. (C) Quantification of bone volume (BV) fraction (BV/total volume [TV], %) within the inner and outer ROIs. The data is presented as mean±standard deviation (N=3). While statistical significance was not reached due to sample size limitations (P>0.05, Mann-Whitney U test), the cover-type group exhibits a higher mean BV, particularly in the inner ROI. 2D, two-dimensional.
Fig. 5 Histological confirmation of enhanced osseointegration and bone-to-implant contact (BIC). (A) Representative hematoxylin and eosin (H&E)-stained sections from the implant-only control and cover-type scaffold-augmented groups at 8 weeks post-implantation. The cover-type group shows new bone trabeculae traversing the scaffold pores to achieve direct contact with the implant surface (bridging the gap), whereas the control group frequently shows interfacial fibrous tissue encapsulation (scale bar=500 μm). (B) Histomorphometric quantification of the BIC (%). The data is presented as mean±standard deviation. The cover-type group demonstrated a statistically significant increase in BIC compared to the control group. a)P<0.05, Mann-Whitney U test.
Graphical abstract
Biomimetic Architectural Cover Accelerates Osseointegration of Titanium Implants