Skip to main navigation Skip to main content
  • KSBMR

JBM : Journal of Bone Metabolism

OPEN ACCESS
ABOUT
BROWSE ARTICLES
EDITORIAL POLICIES
FOR CONTRIBUTORS

Articles

Original Article

Does Bone Mineral Density Differ between Fan-Beam and Pencil-Beam?: A Meta-Analysis and Systemic Review

Journal of Bone Metabolism 2021;28(1):67-77.
Published online: February 28, 2021

1Department of Orthopaedic Surgery, Seoul Paik Hospital, Inje University College of Medicine, Seoul, Korea

2Department of Orthopaedic Surgery, Ewha Womans University Mokdong Hospital, Ewha Womans University College of Medicine, Seoul, Korea

3Department of Orthopaedic Surgery, Gyeongsang National University Hospital, Gyeongsang National University, Jinju, Korea

4Department of Radiology, Chung-Ang University College of Medicine, Seoul, Korea

5Department of Orthopaedic Surgery, Chung-Ang University College of Medicine, Seoul, Korea

Corresponding author: Yong-Chan Ha, Department of Orthopaedic Surgery, Chung-Ang University College of Medicine, 102 Heukseok-ro, Dongjak-gu, Seoul 06973, Korea, Tel: +82-2-6299-1577, Fax: +82-2-822-1710, E-mail: hayongch@naver.com

Byung-Ho Yoon and Young Do Koh contributed equally to this work and should be considered co-first authors.

• Received: January 31, 2021   • Revised: February 14, 2021   • Accepted: February 16, 2021

Copyright © 2021 The Korean Society for Bone and Mineral Research

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

  • 9,336 Views
  • 110 Download
  • 1 Crossref
  • 1 Scopus
prev next

Citations

Citations to this article as recorded by  Crossref logo
  • Cross-Calibration Study of The Stratos And Hologic QDR 4500A Dual-Energy X-Ray Absorptiometers to Assess Bone Mineral Density And Body Composition
    Laurent Maïmoun, Sandrine Alonso, Krishna Kunal Mahadea, Vincent Boudousq, Thibault Mura, Denis Mariano-Goulart
    Journal of Clinical Densitometry.2023; 26(4): 101434.     CrossRef

Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:

Include:

Does Bone Mineral Density Differ between Fan-Beam and Pencil-Beam?: A Meta-Analysis and Systemic Review
J Bone Metab. 2021;28(1):67-77.   Published online February 28, 2021
Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:
Include:
Does Bone Mineral Density Differ between Fan-Beam and Pencil-Beam?: A Meta-Analysis and Systemic Review
J Bone Metab. 2021;28(1):67-77.   Published online February 28, 2021
Close

Figure

  • 0
  • 1
  • 2
  • 3
Does Bone Mineral Density Differ between Fan-Beam and Pencil-Beam?: A Meta-Analysis and Systemic Review
Image Image Image Image
Fig. 1 Preferred Reporting Items for Systematic Reviews and Meta-Analyses flow diagram details the process of relevant study selection.
Fig. 2 Forest plots of the changes of bone mineral density (BMD) determined between pencil-beam mode and fan-beam mode: (A) Total lumbar area. (B) Total hip area. (C) Total body. Effect sizes are indicated as Hedges’ g weighted mean differences and 95% confidence interval (CI).
Fig. 3 Forest plots of the changes of bone mineral density (BMD) determined between fan-beam (FB) mode (Prodigy) and most recent FB mode (iDXA): (A) Total lumbar area. (B) Total hip area. (C) Total body. Effect sizes are indicated as Hedges’ g weighted mean dif ferences and 95% confidence interval (CI).
Fig. 4 Publication bias of included studies. SMD, standard mean difference.
Does Bone Mineral Density Differ between Fan-Beam and Pencil-Beam?: A Meta-Analysis and Systemic Review

Characteristics of included individual studies

References Year Country Type of DXA machine Sample size (female/total) Mean BMI (kg/m2) Mean age (yr)
Morrison et al.[16] 2016 UK Prodigy vs. iDXA 56/92 26.5 39.8
Watson et al.[14] 2017 UK Prodigy vs. iDXA 36/69 26.1 37.8
Saarelainen et al.[15] 2016 Finland Prodigy vs. iDXA 72/72 25.3 42.2
Hind et al.[27] 2015 UK Prodigy vs. iDXA 85 NA NA
Rhodes et al.[17] 2014 UK Prodigy vs. iDXA 43/63 25.6 45.1
Huffman et al.[20] 2005 UK DPX-L vs. Prodigy 34/72 25.9 35.9
Pludowski et al.[18] 2010 Poland DPX-L vs. Prodigy 97/212 1.2 10.8
Cho et al.[19] 2009 Korea Prodigy vs. iDXA 66/100 24.5 49.6
Crabtree et al.[21] 2005 UK DPX-L vs. Prodigy 58/110 NA NA
Blake et al.[22] 2004 UK DPX-L vs. Prodigy 104/135 26.8 57.1
Oldroyd et al.[23] 2003 UK DPX-L vs. Prodigy 44/72 21.6 32.9
Tothill et al.[24] 2001 UK QDR-1000W vs. QDR-4500A 24/41 NA 32.9
Ruetsche et al.[25] 2000 Switzerland QDR-2000W vs. QDR-4500A 63/63 29.3 48
Ellis and Shypailo [26] 1998 USA QDR-2000W vs. QDR-4500A 26/47 NA NA

DXA, dual energy X-ray absorptiometry; BMI, body mass index; NA, non-available.

The mean value±standard deviation of bone mineral density in each included study

References Year N Lumbar total Total hip Total body



Pencil-beam Fan-beam Prodigy iDXA Pencil-beam Fan-beam Prodigy iDXA Pencil-beam Fan-beam Prodigy iDXA
Morrison et al.[16] 2016 92 0.99±0.1 1.05±0.14 - - 1.25±0.13 1.22±0.15

Watson et al.[14] 2017 69 1.25±0.15 1.26±0.15 1.08±0.16 1.08±0.15 1.25±0.16 1.24±0.15

Saarelainen et al.[15] 2016 72 1.16±0.14 1.18±0.14 0.99±0.12 1.00±0.12 - -

Hind et al.[27] 2015 85 1.22±0.14 1.21±0.15 1.05±0.15 1.05±0.15 - -

Rhodes et al.[17] 2014 63 1.16±0.15 1.12±0.14 - - 1.20±0.09 1.18±0.11

Huffman et al.[20] 2005 72 0.92±0.12 0.93±0.12 - - 1.16±0.12 1.19±0.13

Pludowski et al.[18] 2010 212 0.61±0.07 0.63±0.07

Choi et al.[19] 2009 100 1.06±1.18 1.04±1.18 0.93±0.16 0.94±0.16 0.80±0.04 0.80±0.04 - -

Crabtree et al.[21] 2005 110 0.64±0.08 0.64±0.09 - - 0.81±0.04 0.82±0.04

Blake et al.[22] 2004 135 1.00±0.21 0.99±0.21 0.84±0.16 0.84±0.15 - -

Oldroyd et al.[23] 2003 72 1.05±0.17 1.05±0.18 0.90±0.12 0.91±0.12 1.12±0.1 1.12±0.1

Tothill et al.[24] 2001 41 0.84±0.12 0.96±0.13 1.08±0.09 1.16±0.10

Ruetsche et al.[25] 2000 63 1.02±0.14 1.04±0.13 0.78±0.11 0.77±0.11 - -

Ellis and Shypailo [26] 1998 47 - - - - 0.94±0.19 0.94±0.17
Table 1 Characteristics of included individual studies

DXA, dual energy X-ray absorptiometry; BMI, body mass index; NA, non-available.

Table 2 The mean value±standard deviation of bone mineral density in each included study